We are known as a recognized entity of the market, engaged in manufacturing and exporting Industrial Thermic Fluid Heater. This heater is manufactured at our advanced production unit under the guidance of the experts by using high quality materials as per the industry laid quality standards. Our heater is a high capacity heating system that provides maximum efficiency by using several suitable fluids. Industrial Thermic Fluid Heater is available for our wide base of clients at an affordable price.
Features:
Thermic Fluid Heater
Technical Specifications:
MODEL | UNIT | VTFH-04 | VTFH-06 | VTFH-10 | VTFH-15 | VTFH-20 | VTFH-25 |
Heat performance | |||||||
Capacity | Kcal / hr | 4x105 | 6x105 | 1x106 | 1.5x106 | 2x106 | 2.5x106 |
Max .T.F Outlet Temperature | C | 300 | 300 | 300 | 300 | 300 | 300 |
Flow Rate | M3/hr | 30 | 50 | 70 | 120 | 160 | 210 |
Thermal Efficiency (%) | % | 76 | 76 | 76 | 76 | 76 | 76 |
T.F. Head available at outlet | MIC | 27 | |||||
Heater construction features | |||||||
Coil hold up capacity | Litres | 470 | 550 | 1200 | 2350 | 3100 | 3700 |
Material of construction | |||||||
Tubes | | ERW as per BS 3059 part 1 | |||||
Thermic Fluid Pump | |||||||
Flow | M/hr | 30 | 50 | 70 | 120 | 160 | 210 |
Head | M3/hr | 50 | 50 | 50 | 50 | 50 | 50 |
Power | HP | 10 | 15 | 25 | 30 | 40 | 50 |
Connected load | |||||||
Coal or Lignite | HP | 17 | 25.5 | 40 | 47.5 | 62.5 | 80 |
Wood | HP | 17 | 25.5 | 40 | 47.5 | 62.5 | 80 |
Husk | HP | 21 | 31 | 47 | 53 | 75 | 95 |
Fuel Consumption | |||||||
Coal | Kg/hr | 117 | 175 | 292 | 439 | 585 | 731 |
Wood | Kg/hr | 165 | 247 | 411 | 617 | 823 | 1128 |
Husk | Kg/hr | 188 | 282 | 470 | 705 | 940 | 1175 |
Lignite | Kg/hr | 176 | 263 | 439 | 658 | 877 | 1097 |
TECHNICAL SPECIFICATION OF SOLID FUEL FIRED IN HORIZONTAL THERMIC FLUID HEATER | |||||||||||
DETAIL | UNIT | HTFH10 | HTFH20 | HTFH030 | HTFH040 | HTFH60 | HTFH100 | HTFH150 | HTFH200 | HTFH250 | |
Heat Output | Kcal/Hr | 1,00,000 | 2,00,000 | 3,00,000 | 4,00,000 | 6,00,000 | 10,00,000 | 15,00,000 | 20,00,000 | 25,00,000 | |
Outlet Temp | Degree C | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | |
Thermal Efficiency | +-2 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
Fuel Consumption | LIGNITE | Kg/hr | 48 | 95 | 142 | 190 | 285 | 476 | 719 | 952 | 1190 |
COAL | Kg/hr | 32 | 64 | 96 | 128 | 192 | 320 | 476 | 635 | 794 | |
WOOD | Kg/hr | 45 | 90 | 135 | 180 | 270 | 445 | 670 | 893 | 1116 | |
Electric Load Thermic Fluid Pump | HP | 5 | 7.5 | 7.5 | 10 | 15 | 20 | 30 | 40 | 50 | |
Overall Dimensions | | ||||||||||
Length | mm | 3215 | 3915 | 425 | 5690 | 6505 | 7115 | | | | |
Width | mm | 2120 | 2465 | 3120 | 3330 | 3940 | 4090 | | | | |
Height | mm | 1230 | 1575 | 2115 | 2365 | 2365 | 2795 | | | |